Introduction


CB-32 Series transmitters are isolated transmitter modules with a current input and two-wire current loops from 4 to 20 mA at the output. They have an input voltage converter, protection system, filters, isolation circuits and output current driver from 4 to 20mA. Output, current signal is suitable for transmission at a distance of 1200m to the data acquisition system, Industrial PC, PLC or to some other measurement system.

The CB-32 family of insulation modules protect people and measure equipment and galvanically isolate them from ecstatic events that may appear on the sensor side or somewhere else within a measuring environment. The input and output of the modules are protected from transients and voltage levels up to 250Vrms. Transmitters have a very low cost price and excellent features that only meet very expensive devices. The input and output of the module is protected from transients and voltage levels up to 250Vrms.

 

CB transmitter Series have a chopper input amplifier with low temperature drift, low offset and very stable gain coefficient. The amplifier is determined by two precise voltage references. The transmitter operates on the principle of amplitude modulation and transformer isolation of the signal so that the primary side of the module is "floating" in relation to the secondary side of the module. This architecture gives excellent linearity, stable and reliable characteristics and does not require input grounding. The signal demodulator on the output (secondary) side of the module restores the original signal, which is then filtered and converted to a 4 to 20 mA current signal.

 

 

Attributes


  • Instrumentation accuracy, linearity, repeatability and reliability

  • Current input and current output from 4 to 20mA

  • Transformer isolation min. 1500Vrms

  • ±0.03% Accuracy

  • ±0.01% Linearity

  • 80dB NMR for 50Hz

  • 160dB CMR

  • Power supply of the conditioner from 11V to 60V through the current loop

  • Input and output protected from 250V continuously 

  • Easy installation on DIN rail

  • Transient protection according to ANSI / IEEE C37.90.1-1989 specification

  • Meets CSA, FM and CE specifications

  • The warranty period is 7 years, and the service period is 10 years

 

 

Block diagram of CB-30 isolation transmitters

Characterization


The input circuit provides protection against incorrectly connected voltages up to 250 VAC and protection against transients defined by ANSI / IEEE C37.90.1-1989 documents. The transmitters have a fifth-line filter, which suppresses 50 Hz  with 80 dB (min. 10,000 times). An Anti-Aliasing Pole Filter (LPF) is located in the primary circuit of the module, while on the secondary side of the isolation barrier there is a fourth-order filter. After the Anti-aliasing filtering on the input side of the conditioner, the signal is applied to the chopper level behind the insulating micro transformer. The signal transmission method is amplitude modulation. This technique provides better results than the technique with linear opto-scanners or capacitor isolation techniques. In the secondary stage, behind the isolation barrier, the signal is demodulated and filtered again from the transmission interference.

 

The power supply of the transmitter is via a loop in the range of 11 to 60V DC. The power supply level of the module has a built-in protection circuit for inverse power supply voltage and circuits that prevent passage of transitions. The module has excellent stability in time and does not require calibration or any maintenance. On the front of the module below the front sticker there are two multi-port trimmers for precise adjustment of the offset and the zero. Both values are set before delivery and the user can overbalance these values according to their needs in the range of ± 10%

 

The CB-32 transmitter family can be mixed in the same application with other families of isolation modules. They can be plugged into the measuring system and disconnected from it without turning off the power of the system or shutting down the system.

 

Power supply for transmitters



For power supply up to 50 transmitters, the CS-PS-48, 48W power supply  (left-hand) is recommended, while the power supply of a number of conditioners should use a CS-24-90 of 90W power supply, which can, under full load, power up to three times more transmitters, although such a large number of transmitters are recommended to be powered from multiple el. sources. Transmitters do not support the rail T-BUS connector because they are powered through a loop.

 

The CS-PS-48 source operates in a wide voltage range from 85V to 265V AC. Both power sources operate in a wide voltage range from 160V to 265V AC. If the user does not want to use this type of power, it can also use other electrical sources.

 

 

The PCB of conditioner can be protected, on request, with special lacquer that protects electronic components from moisture, corrosion and other types of contamination, which can significantly extend the life of this product and in terms of long-term measurement accuracy. This conditioned conditioner can be applied in many aggressive environments. For example: on ships or on the seashore, in conditions of aggressive vapors, acid, water and other places with high humidity, etc.

 

Picture left: Power supply CS-24-30

 

 

 

Specifications and characteristics


(tipically at 25°C)

 

 Parameter CB-32 current input
 Input converting measuring resistor  47.00 Ohms
 Output range 4 to 20 mA
 Under range 3 mA
 Maximum overload current 30 mA
 Reverse polarity Continuous
 KContinuous input protection max. 250 Vrms
 Transients ANSI/IEEE C37.90.1- 1989
 CMV, ulaz-izlaz Continuously 1500 Vrms
 CMR 50Hz  105 dB
 Accuracy 25 ° C ±0.03% of range
 Non-linearity ±0.01% of range
 Subsequent settings ±10% offset and gain
 Stability of input offset ±0.5 µV/°C
 Output offset ±30 ppm/°C
 Stability of gain ±90 ppm/°C
 Frequency bandwidth -3 dB 100 Hz  (Options:  5 kHz and 10 kHz)
 Response Time, Span 90%  10 ms max.
 NMR 80 dB 100 Hz
 Power loop From 11 V to 60 V
 Loop stability ±0,0005 % /V
 Temperature range (ambient) -40 ÷ 85 °C
 Working range within the specification -40 ÷ 80 °C
 Storage -40 ÷ 85 °C
 Relative Humidity Without condensation 0 to 95 %
 Immunity EN50082-1, ISM Group 1 Class A
 Rail mounting DIN EN50022 35 x 7,5
 Dimensions of the conditioner mm L:114 x W:.22,5 x H:105

 

Prices and specifications can be changed

Prices and types


 

 

 Oznaka  Ulaz  Izlaz Cena €
 1-49
Cena €
 50-99 
Cena €
   100+  

CB-32-00

0 to 5mA 4 to 20mA 79 65 55

CB-32-01

0 to 10mA 4 to 20mA 79 65 55

CB-32-02

0 to 20mA 4 to 20mA 79 65 55

CB-32-03

4 to 20mA 4 to 20mA 79 65 55

CB-32-04

 5 to 25mA 4 to 20mA 79 65 55

CB-32-05

 ±5mA 4 to 20mA 79 65 55

CB-32-06

 ±10mA

4 to 20mA 79 65 55

CB-32-07

 ±20mA 4 to 20mA 79 65 55

CB-32-08

 ±50mA 4 to 20mA 79 65 55

CB-32-09

 ±100mA 4 to 20mA 79 65 55

CB-32-10

 ±200mA 4 to 20mA 79 65 55

CB-32-11

 ±500mA 4 to 20mA 79 65 55

CB-32-12

 0 to 1A 4 to 20mA 79 65 55

CB-32-13

 0 to 2A 4 to 20mA 79 65 55

CB-32-14

 0 to 5A 4 to 20mA 89 75 65

CB-32-15

 0 to 10A 4 to 20mA 99 85 70

CB-32-16

 0 to 15A 4 to 20mA 110 95 80

 

Prices are without VAT.

  

   Option 1. Transmitters typically have a frequency band of 3 Hz. For a bandwidth of 1 kHz or 10 kHz (-3 dB), the price is 3 € higher.

   Option 2. Commodity-protected transmitters for high-humidity environments have a 10 € higher price.  

   Option 3. Transmitters artificially tested with the Burn-in process, 48 hours at 60°C have a 15 € higher price.

   Option 4. Transmitters by special user specification: the first piece is 150 €.

 